Vents and airflow¶
Vents decide which space a system conditions. A system only reaches the blocks its vents can blow air (or water) into.
Linking vents¶
/hvac link-tool ("duct-tool" and "tool" still work)
- Right-click the system's thermostat to select it.
- Right-click vent blocks in the same world to link them.
- Sneak-right-click a vent to unlink it.
Only blocks you link become vents.
| Vent block | Conditions | Fed by |
|---|---|---|
| Iron trapdoor | the room around it | heat pumps, air conditioners, furnaces |
| Waxed copper grate, placed in water | the water around it | boilers, pool heat pumps |
A system is all air or all water, and its equipment must match: linking a grate to an air system, or a trapdoor to a pool system, is refused.
How far air reaches¶
Each vent spreads air in all six directions through open space:
- 0-15 blocks of airflow get the full thermostat temperature (the core).
- 16-30 blocks blend back toward the outdoor temperature (the edge).
- Beyond 30 the system has no effect.
Distance is counted along the path the air takes, not in a straight line, so air goes around corners and through doorways but not through walls.
What air passes through¶
- Open space and passable blocks carry air.
- Solid blocks and liquids stop it.
- Doors and trapdoors pass air when open and stop it when closed.
- Carpets (wool and moss) pass air, so a carpeted floor is still part of the room.
When you open a door or break a wall, the system's airflow updates about a
second later. More vents cover more of a big space. Blocks changed by
commands such as /fill or WorldEdit don't tell EZvac; run /hvac sync
afterwards to map every system again.
Roofs and the outdoors¶
New in BETA 1.0, with sizing. Air under a roof goes as far as its vents reach. Once it steps out under open sky, through a door, a window or off a patio, it only goes 3 blocks further before the outdoors swallows it:
vent (10 blocks inside) roof ends
##############################################
. . . . . . . . . . . . . . . . . . . [door] 1 2 3 x
##############################################
- Roofed means a solid block somewhere above, glass included. Leaves don't count.
- Once out, air stays out. A roof it finds after being under open sky (an overhang, a porch, the building next door) doesn't make it indoors again: the 3 blocks still count. So does cover with open sky beside it, such as the strip under an eave or a doorway, so air doesn't run round a house under its overhang.
- A porch or loggia reached through a door, without going out, is part of the room where nothing beside it is open sky.
- A vent out in the open cools a small bubble around it, not a field.
- Every block of opening (each block of a doorway or window, or a hole in the roof) makes the room leak more, so it drifts toward the outdoor temperature faster. Only where the inside meets the sky counts: a doorway is 2 openings, whatever lies beyond it.
- The Nether is all roofed, so nothing changes there.
sizing.outdoor-reach sets the 3 blocks. With building size off, air goes
the whole 30 blocks outdoors, as before BETA 1.0.
Water systems (pools)¶
A pool works exactly like a room, through water instead of air:
- Build a boiler or pool heat pump in a casing (see Equipment).
- Place a sign and run
/hvac create thermostat <label> [target]. - With the link tool, select the thermostat, then link the boiler and put waxed copper grates in the pool and link them. The thermostat becomes a pool thermostat (75-104 °F) as soon as the first one is linked.
side view of a pool:
[edge ][water][water][water][edge ]
[edge ][water][GRATE][water][edge ] <- a linked waxed copper grate
[edge ][edge ][edge ][edge ][edge ]
- Water systems travel through water and stop at everything else.
- Only the waxed copper grate counts. Waxed copper never oxidises, so a vent can't change by itself. Scraping the wax off with an axe unregisters the vent, the same as breaking it.
- Water keeps its own temperature: water no pool system reaches (lakes, the sea, an unheated pool) reads the biome's natural water temperature, steady, with no day/night swing. The edge of a heated pool blends toward that, not toward the air.
- The thermostat, timers, multiple units and ETA all behave as they do for a room.
Good to know¶
- Airflow never loads chunks, and big edits (WorldEdit, FAWE) are handled without slowing the server; see Vents and airflow in features.txt for the limits.
- Each system covers at most 200,000 blocks of airflow by default.
- A dehumidifier's grate can't also be a water vent.