Skip to content

Vents and airflow

Vents decide which space a system conditions. A system only reaches the blocks its vents can blow air (or water) into.

Linking vents

/hvac link-tool        ("duct-tool" and "tool" still work)
  1. Right-click the system's thermostat to select it.
  2. Right-click vent blocks in the same world to link them.
  3. Sneak-right-click a vent to unlink it.

Only blocks you link become vents.

Vent block Conditions Fed by
Iron trapdoor the room around it heat pumps, air conditioners, furnaces
Waxed copper grate, placed in water the water around it boilers, pool heat pumps

A system is all air or all water, and its equipment must match: linking a grate to an air system, or a trapdoor to a pool system, is refused.

How far air reaches

Each vent spreads air in all six directions through open space:

  • 0-15 blocks of airflow get the full thermostat temperature (the core).
  • 16-30 blocks blend back toward the outdoor temperature (the edge).
  • Beyond 30 the system has no effect.

Distance is counted along the path the air takes, not in a straight line, so air goes around corners and through doorways but not through walls.

What air passes through

  • Open space and passable blocks carry air.
  • Solid blocks and liquids stop it.
  • Doors and trapdoors pass air when open and stop it when closed.
  • Carpets (wool and moss) pass air, so a carpeted floor is still part of the room.

When you open a door or break a wall, the system's airflow updates about a second later. More vents cover more of a big space. Blocks changed by commands such as /fill or WorldEdit don't tell EZvac; run /hvac sync afterwards to map every system again.

Roofs and the outdoors

New in BETA 1.0, with sizing. Air under a roof goes as far as its vents reach. Once it steps out under open sky, through a door, a window or off a patio, it only goes 3 blocks further before the outdoors swallows it:

 vent (10 blocks inside)                roof ends
 ##############################################
 . . . . . . . . . . . . . . . . . . . [door]  1  2  3  x
 ##############################################
  • Roofed means a solid block somewhere above, glass included. Leaves don't count.
  • Once out, air stays out. A roof it finds after being under open sky (an overhang, a porch, the building next door) doesn't make it indoors again: the 3 blocks still count. So does cover with open sky beside it, such as the strip under an eave or a doorway, so air doesn't run round a house under its overhang.
  • A porch or loggia reached through a door, without going out, is part of the room where nothing beside it is open sky.
  • A vent out in the open cools a small bubble around it, not a field.
  • Every block of opening (each block of a doorway or window, or a hole in the roof) makes the room leak more, so it drifts toward the outdoor temperature faster. Only where the inside meets the sky counts: a doorway is 2 openings, whatever lies beyond it.
  • The Nether is all roofed, so nothing changes there.

sizing.outdoor-reach sets the 3 blocks. With building size off, air goes the whole 30 blocks outdoors, as before BETA 1.0.

Water systems (pools)

A pool works exactly like a room, through water instead of air:

  1. Build a boiler or pool heat pump in a casing (see Equipment).
  2. Place a sign and run /hvac create thermostat <label> [target].
  3. With the link tool, select the thermostat, then link the boiler and put waxed copper grates in the pool and link them. The thermostat becomes a pool thermostat (75-104 °F) as soon as the first one is linked.
 side view of a pool:

 [edge ][water][water][water][edge ]
 [edge ][water][GRATE][water][edge ]   <- a linked waxed copper grate
 [edge ][edge ][edge ][edge ][edge ]
  • Water systems travel through water and stop at everything else.
  • Only the waxed copper grate counts. Waxed copper never oxidises, so a vent can't change by itself. Scraping the wax off with an axe unregisters the vent, the same as breaking it.
  • Water keeps its own temperature: water no pool system reaches (lakes, the sea, an unheated pool) reads the biome's natural water temperature, steady, with no day/night swing. The edge of a heated pool blends toward that, not toward the air.
  • The thermostat, timers, multiple units and ETA all behave as they do for a room.

Good to know

  • Airflow never loads chunks, and big edits (WorldEdit, FAWE) are handled without slowing the server; see Vents and airflow in features.txt for the limits.
  • Each system covers at most 200,000 blocks of airflow by default.
  • A dehumidifier's grate can't also be a water vent.